As you can imagine, often you must plan forward to be sure that your rafters are sized adequately to allow for insulation and venting. For more info on acceptable approaches to insulate lower-slope roofs, see this post: Insulating Lower-Slope Residential Roofs.

The initial vent baffles to strike the marketplace — the basic Appropriate-Vent with the nineteen seventies and ’80s — ended up reasonably priced, flimsy merchandise product of thin polystyrene. Polystyrene baffles have numerous shortcomings: staying slim and flexible, they are able to’t resist the pressures from dense-packed cellulose or blown-in fiberglass; they don’t ventilate the entire width with the rafter bay; and as normally installed, they permit air to leak out the top on the insulated assembly.

The plan is to install it (from the inside of your house) about exactly the same time the drywall is put up. I will instruct my crew to make sure there aren't any air pockets in the purlin cavities & no air move into your latter.

Install rigid foam insulation above the roof sheathing and air-permeable insulation among the rafters. Such a assembly is made to dry to the interior, And so the assembly should really never ever include things like an inside polyethylene vapor barrier. If you choose this technique, it’s doable (however not important) to set up vent channels amongst the best on the rigid foam and the highest layer of roof sheathing by setting up a series of parallel 2x4s — a person previously mentioned Just about every rafter — extending from soffit to ridge. (For more information on this method, see How to Install Rigid Foam On Top of Roof Sheathing.)

The longer that you wait to install rigid foam higher than your roof sheathing right after your rafter bays are crammed with fluffy insulation, the larger the chance that your roof sheathing will accumulate humidity. 1 or 2 several years should be no challenge, but I wouldn't stretch the workout A lot farther than that.

Thanks for that comments. We won't ever A/C the constructing (It will probably be solar powered). you can try these out The wind is rather constant, but it is a humid setting, so dampness control is absolutely on my brain.

Please enter any prior references (past clientele) that you have got labored with separated by typing Enter

Many thanks Martin - Now I see why my first plan for just a SIPS envelope was so elegantly basic. It looks like min R-ten sprayed beneath the roof sheathing and after roofing company ann arbor that a complete-fill of the bays with batt / fluffy, and a vapor sealed drywall lid will get me the 'scorching' (unvented) roof process the SIPS was from your get go.

Martin, Thank you for the reply. Those content are equally very insightful. see I am getting the sense that SIPs can be done perfectly, but could be defeat in price with exterior rigid foam programs while you've suggested, with equal or better functionality (with emphasis on air-tightness).

As the house flexes with adjustments of temperature It really is attainable, even likely that several of the foamed-in air sealing will leak. It'd be worth undertaking two" of open up cell foam on the interior side of which might be a more flexible and reliable long phrase air seal.

Yesterday we blew the insulation and set up the SIGA Majcoat on the CAPACES Leadership Institute. There was a lot more than 8,000 Cubic toes of insulation to install, so our insulators had 2 in their blower trucks and a superb crew on site. They were blowing cellulose as quickly as they could plus the the rain was heading our way. Below 45 minutes once the insulation was accomplished we experienced completed the Majcoat and had been occupied taping seams.

Confident the example proven is for just a lower pitch (not flat) roof. But adjust it to some pitched roof under 6-twelve and the small print are still an excellent technique (I feel).

The GBA website does not give tailor made information. That's what an architect or an engineer is for; I recommend that you hire 1.

I have a great deal of walls to re-insulate, and once the roof is dealt with I'll have rafter bays to insulate, and It could be valuable to own some Perception into which sort of fiberglass provides what advantage for its cost.