I am including a photograph of the solution: spray foam held down in the best edge of the rafters so that air could be drawn up from soffit vents to gable vents while in the truncated attic cavity.

Any property remaining designed better than absolutely the minimums should on the really least not use OSB for roof sheathing. Imo

If it seems like I'm away from my depth here... yeah, you guess, I am. I'm only a homeowner, with only a few times of Web study less than my belt. Though the contractor just isn't common with this roofing technique, so we are needing to determine it out jointly. Respect your enable immensely.

Predicament comparable to Eric, previously mentioned. If closed cell foam is sprayed or "cobbled" from xps, do It's important to fill your entire Area, or only to thickness for ideal R worth?

I believe that you need to submit a sketch. I can't visualize what you are speaking about from a description. If you wish to put in an HRV in your attic, How come you need to install a watertight stucco roof about some sort of EPS box? Isn't really your attic by now dry? Most attics have roofs.

You're in weather zone 5. I described the minimum R-values for your method you're using in on the list of paragraphs earlier mentioned, through which I wrote, "In keeping with .

According to part R806.3 from the 2006 International Residential Code (IRC), “At least a 1-inch House shall be delivered in between the insulation plus the roof sheathing and at the location from find more info the vent.” Such a vent Room is often produced by setting up one inch by 1 inch “sticks” from the upper corners of each and every rafter bay, accompanied by rigid cardboard, slender plywood, OSB, fiberboard sheathing, or panels of rigid foam insulation.

Editor's Observe: A solution to this question continues to be posted on Site 3. Simply click the box below to get to the up coming remark webpage.

Initially, could it be straightforward to establish regardless of whether a roof is ventilated? If no soffit vents or facet vents are obvious around the roof in the ground, does that suggest the roof is just not ventilated?

My understanding as I look at this blog is that I do not need to worry about building an air channel over the sheathed portion due to rigid foam.

Your assembly requires about 5 inches of XPS, for a complete R-worth of only R-twenty five. That's not Substantially. Should you are going to all that hassle to develop a complicated roof assembly, you ought to aim higher.

It is best to seek advice from an electrician about the best way to provide your ceiling electrical boxes. There are several achievable answers -- some obvious from the interior, and many concealed by the new foam.

Am i able to get some far more commentary over the "full roof" of Ice & Drinking water Shield? I do think click here to find out more this experienced pretty little to complete with the failure. The rationale why I question is I have an analogous "entire roof" layout coming up, Nevertheless, the rafter bays are all straight operates with soffit vents, constant vent baffles (one/two" plywood) roofing company albany ny and continuous ridge vent. Dense pack cellulose, two" XPS below 2x10's, air limited drywall (XPS may be sealed up far too).

Have you been thinking the 'flat' vented cavities would not give the assembly with an exhaust path for humidity?